Megohmmeter 1000V CAT. III & 600V CAT. IV

SKU
OE 4002
Product values View all features
Specially designed for hybrid and electric vehicles, this device can measure the insulation of electrical equipment, as well as voltages up to 1000V. It measures DC and AC voltage, DC and AC current, temperature, resistance, capacitance, insulation and frequency.
GARANTIE2.jpg PILES.jpg PL.jpg TENSION1000V.jpg VL.jpg VUL.jpg MOTO.jpg TN.jpg
429 VAT Excl. €0.21
Add to Wish List

Characteristics

More Information
Item name Megohmmeter 1000V CAT. III & 600V CAT. IV
Bar code 3700461471568
Introduction Specially designed for hybrid and electric vehicles, this device can measure the insulation of electrical equipment, as well as voltages up to 1000V.
It measures DC and AC voltage, DC and AC current, temperature, resistance, capacitance, insulation and frequency.
Text Adapted to the "low voltage" requirements of : BCL, B2VL , B2TL , B2XL ...
Product highlight Suitable for hybrid and electric vehicles
Specifications Specifications:
Complies with the IEC/EN 61010-1 standard: 1000 V CAT III, 600 V CAT IV.
DC voltage: 1000 V; AC voltage: 750 V (TRMS).
- DC voltage: 600 mV–6 V–60 V–600 V–1000 V
- AC voltage: 600 mV–6 V–60 V–600 V–750 V
- DC current: 60 mA–400 mA
- AC current: 60 mA–400 mA
- 6,600 counts (except for capacitance, temperature, and insulation measurements)
- When the input terminals are V and COM, the voltage overload protection is up to 250 V AC (TRMS).
- When the input terminals are mA and COM, the current overload protection is 0.4 A.
- When the input terminals are Hi and Lo, the protective voltage overload is 600 V.
- Displays minimum, maximum, and average values
- 4 AA batteries (NEDA 15A or IEC LR6) providing 1,000 hours of battery life for insulation testing.
- The multimeter can perform at least 1,000 insulation tests with new alkaline batteries at room temperature.
These are standard 1,000 V tests at 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
- Resistance: 600 ohms–6 kohms–60 kohms–600 kohms–6 MΩ–60 MΩ
- Insulation measurement range: 0.01 MΩ to 2 GΩ.
- Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1,000 V.
- Insulation reference voltage: +20%, -0%.
- Insulation short-circuit test current: 1.5 mA nominal.
- Automatic insulation discharge: discharge time <1 second for C = 1 μF or less.
- Live insulation circuit detection: Stop the test if the voltage at the terminal is >20V before the test begins.
- Insulation resistance: 50V (5–50 Mohm) - 100 V (0–100 MΩ) - 250 V (0–250 MΩ) - 500 V (0–500 MΩ) - 1,000 V (0–2 GΩ)
- Automatic calculation of the dielectric absorption ratio (DAR) and polarization index (PI)
- Maximum capacitive load on the insulation: operates up to a load of 1 μF.
- Storage temperature: -40°C to 60°C.
- Operating temperature: 0°C to 40°C.
- Storage altitude: 12,000 m
- Operating altitude: 2,000 m at 1,000 V CAT III, 3,000 m at 1,000 V CAT II
- Temperature: -30 to 1,300°C
- Temperature coefficient: 0.05 × (specified accuracy) per °C for temperatures <18°C or >28°C.
- Relative humidity: 40%–75%.
- Dimensions: 205 (L) × 102 (W) × 58 (H) mm.
- Weight: approximately 390 g.
- Electrical safety categories: CAT III 1000 V; this device may be used in a Category 3 environment (as shown in the table on the left) at a maximum voltage of 1000 V, and in a Category 4 environment at a maximum voltage of 600 V.
Contents Contents:
- 1x Megohmmeter
- 1x pair of test leads
- 1x pair of alligator pliers
- 1x MS 3204 plug
- 1x temperature probe (Type K thermocouple)
- 1x carrying case
- 1x carrying strap (shoulder strap)
- 4x LR6 batteries
Warranty period 2 years
Voltage 1000V
More Powered by battery
Cable length 1.20 m
Length (mm) 205 mm
Width 102 mm
Height 58 mm
Tariff code Tariff Normal (TN)
Warranty Procedure DIAGNOSTIC
Customer benefit This insulation tester complies with CESVI France's quality standards and expectations.

has as After sales service & consumables